Fluke FLK-TI300 9Hz 320 x 240 Thermal Camera
$ 98.60
Features: 320 x 240 resolution 2 meter drop test LaserSharp™ Auto Focus Manual or automatic focus Measure up to 650 °C Specifications: IFOV with standard lens (spatial resolution): 1.85 mRad, D:S 532:1 Detector resolution: 320 x 240 SuperResolution: No Infrared Resolution: 76,800 pixels MultiSharp™ Focus: No LaserSharp Auto Focus: Yes, for consistently in-focus images Laser distance meter: Yes, calculates distance to the target for precisely focused images and displays distance on screen Advanced manual focus: Yes Ruggedized touchscreen display: 3.5 inch (landscape) 640 x 480 LCD Rugged, ergonomic design for one-handed use: Yes Digital zoom: No Temperature measurement range (not calibrated below -10 °C): -20 °C to 650 °C (-4 °F to 1202 °F) Accuracy: ±2 °C or 2% (at 25 °C nominal, whichever is greater) Thermal sensitivity (NETD)*: ≤ 0.075 °C at 30 °C target temp (75 mK) On-screen emissivity correction: Yes (both value and table) On-screen reflected background temperature compensation: Yes On-screen transmission correction: Yes IR-Fusion technology: Adds the context of the visible details to your infrared image AutoBlend mode: Min, Mid, Max IR plus full visible on camera; continously variable in software Picture-In-Picture (PIP): Yes Built-in digital camera (visible light): 5 MP Lenses: Standard lens Optional 2x telephoto smart lens Optional 4x telephoto smart lens Optional wide-angle smart lens Extensive memory options: Removable 4 GB micro SD memory card, 4 GB internal flash memory, save to USB flash drive capability, upload to Fluke Cloud™ for permanent storage Image capture, review, save mechanism: One-handed image capture,review, and save capability Image file formats: Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2); no analysis software required for non-radiometric (.bmp, .jpg and .avi) files Memory review: Thumbnail and fullscreen review Laser pointer: Yes Frame rate: < 60 Hz Color alarms: High temperature, low temperature, isotherms (within range) Infrared spectral band: 7.5 μm to 14 μm Operating temperature: -10 °C to 50 °C (14 °F to 122 °F) Storage temperature: -20 °C to 50 °C (-4 °F to 122 °F) without batteries Relative humidity: 10 % to 95 %, non-condensing Center-point temperature measurement: yes Spot temperature: Hot and cold spot markers User-definable spot markers: 3 User defined measurement boxes: Expandable-contractible measurement box Safety standards: IEC 61010-1: Overvoltage category II, Pollution Degree 2 Electromagnetic combability: IEC 61326-1: Basic EM environment. CISPR 11: Group 1, Class A Australian RCM: IEC 61326-1 Vibration: 0.03 g2/Hz (3.8 g), 2.5 g IEC 60068-2-6 Shock: 25g, IEC 68-2-29 Dimensions (L x W x H): 277mm x 122mm x 167mm Weight: 1.04kg Warranty: 2 year warranty covered by Fluke




